A product of VULCAN-HART LOUISVILLE, KY 40201-0696
Form 24627 (12/98)
- NOTICE -
This Manual is prepared for the use of trained Vulcan Service
Technicians and should not be used by those not properly
qualified. If you have attended a Vulcan Service School for this
product, you may be qualified to perform all the procedures
described in this manual.
This manual is not intended to be all encompassing. If you have
not attended a Vulcan Service School for this product, you should
read, in its entirety, the repair procedure you wish to perform to
determine if you have the necessary tools, instruments and skills
required to perform the procedure. Procedures for which you do
not have the necessary tools, instruments and skills should be
performed by a trained Vulcan Service Technician.
Reproduction or other use of this Manual, without the express
written consent of Vulcan, is prohibited.
VSX24G SHOWN
SERVICE MANUAL
VSX BOILER BASE SERIES
CONVECTION STEAMERS
(GAS, ELECTRIC, DIRECT AND REGENERATED)
VSX24G ML-52163 VSX24D ML-52827
VSX36G ML-52360 VSX36D ML-52830
VSX42GT ML-52376 VSX42DT ML-52834
VSX24E ML-52164 VSX36R ML-52831
VSX36E ML-52829 VSX42RT ML-52835
VSX42ET ML-52833
Vue de la page 0
1 2 3 4 5 6 ... 79 80

Résumé du contenu

Page 1 - SERVICE MANUAL

A product of VULCAN-HART LOUISVILLE, KY 40201-0696Form 24627 (12/98)

Page 2 - TABLE OF CONTENTS

VSX SERIES STEAMERS - COMPONENT FUNCTION AND LOCATIONPage 10 of 80COMPONENT FUNCTION AND LOCATIONCABINET BASE BOILERCONTROLSWARNING: THE STEAMER AND

Page 3

VSX SERIES STEAMERS - COMPONENT FUNCTION AND LOCATIONPage 11 of 80Pressure Gauge - indicates boiler steam pressure.Normal operating pressures are lis

Page 4 - INTRODUCTION

VSX SERIES STEAMERS - COMPONENT FUNCTION AND LOCATIONPage 12 of 80

Page 5 - SPECIFICATIONS

VSX SERIES STEAMERS - COMPONENT FUNCTION AND LOCATIONPage 13 of 80

Page 6 - WATER CONDITIONING

VSX SERIES STEAMERS - COMPONENT FUNCTION AND LOCATIONPage 14 of 80COOKING COMPARTMENTCONTROLSWARNING: THE STEAMER AND ITS PARTS AREHOT. USE CARE WHEN

Page 7 - STEAMER OPERATION

VSX SERIES STEAMER - SERVICE PROCEDURESPage 15 of 80SERVICE PROCEDURESWARNING: CERTAIN PROCEDURES IN THIS SECTION REQUIRES ELECTRICAL TEST ORMEASUREM

Page 8 - STEAMER SHUT OFF

VSX SERIES STEAMER - SERVICE PROCEDURESPage 16 of 8010. Cooking compartment timers are to be in theOFF position. Turn the boiler switch ON andopen wa

Page 9

VSX SERIES STEAMER - SERVICE PROCEDURESPage 17 of 80C. Does the HL LED go out and the HL relayde-energize, allowing the contact state toswitch back t

Page 10 - CONTROLS

VSX SERIES STEAMER - SERVICE PROCEDURESPage 18 of 80High Limit ThermostatWARNING: DISCONNECT THE ELECTRICALPOWER TO THE MACHINE AT THE MAINCIRCUIT BO

Page 11

VSX SERIES STEAMER - SERVICE PROCEDURESPage 19 of 804. Remove the stem locking nut to remove thestem from the valve body.5. All parts are now accessi

Page 12 - Page 12 of 80

VSX SERIES STEAMERSPage 2 of 80TABLE OF CONTENTSGENERAL... 4Introduction ..

Page 13 - Page 13 of 80

VSX SERIES STEAMER - SERVICE PROCEDURESPage 20 of 80Steamer Achieves Pressure Slower Than NormalIf the boiler requires more than 15 minutes (20minute

Page 14 - COOKING COMPARTMENT

VSX SERIES STEAMER - SERVICE PROCEDURESPage 21 of 80Inlet Water StrainerThe in-line Y strainer should be located upstream ofthe fill valve solenoid.

Page 15 - SERVICE PROCEDURES

VSX SERIES STEAMER - SERVICE PROCEDURESPage 22 of 80Check the thermocouple output voltage (DCmillivolts) with a VOM. If a meter is not available,repl

Page 16

VSX SERIES STEAMER - SERVICE PROCEDURESPage 23 of 80Spark Ignition Control Test1. If the ignition control module does not appearto be sparking to ign

Page 17 - CYCLING HIGH LIMIT

VSX SERIES STEAMER - SERVICE PROCEDURESPage 24 of 80A. If other appliances are connected to thesame gas line, turn them all ON and checkmanometer pre

Page 18

VSX SERIES STEAMER - SERVICE PROCEDURESPage 25 of 803. Remove the lead wires from the heating element and check the element resistance using a VOM.A.

Page 19

VSX SERIES STEAMER - SERVICE PROCEDURESPage 26 of 80DIRECT STEAM MODELSThese models consist of a pressure regulator andgauge that run off a buildings

Page 20

VSX SERIES STEAMER - SERVICE PROCEDURESPage 27 of 80Water Accumulating in Compartment - Wateraccumulation on the bottom of the cookingcompartment(s)

Page 21 - GAS MODELS

VSX SERIES STEAMER - SERVICE PROCEDURESPage 28 of 80Sealing Adjustment1. Check the door gasket quality. If damaged orworn, replace as outlined in “RE

Page 22

VSX SERIES STEAMER - SERVICE PROCEDURESPage 29 of 80Latch AdjustmentShould the cooker door jam and can not be opened,DO NOT FORCE OR PRY the door as

Page 23

VSX SERIES STEAMERSPage 3 of 80ELECTRICAL OPERATION ... 30Water Level Controls...

Page 24 - ELECTRIC MODELS

VSX SERIES STEAMER - ELECTRICAL OPERATIONPage 30 of 80ELECTRICAL OPERATIONWATER LEVEL CONTROLSSolid State - Low level Cut-Off & Differential Cont

Page 25

VSX SERIES STEAMER - ELECTRICAL OPERATIONPage 31 of 80Solid State - Auxiliary Low Level Cut-OffThis control serves as a safety backup to the mainwate

Page 26

VSX SERIES STEAMER - ELECTRICAL OPERATIONPage 32 of 80Electro Mechanical - Low level Cut-Off & Differential ControlThe steamer is equipped with t

Page 27

VSX SERIES STEAMER - ELECTRICAL OPERATIONPage 33 of 80Electro Mechanical - Auxiliary Low Level Cut-OffThis control serves as a safety backup to the m

Page 28

VSX SERIES STEAMER - ELECTRICAL OPERATIONPage 34 of 80SEQUENCE OF OPERATIONGAS MODELSThis sequence of operation is written for steamerswith automatic

Page 29

VSX SERIES STEAMER - ELECTRICAL OPERATIONPage 35 of 80A. Power to terminal 9 on the water levelcontrol.1) LLCO relay energizes, LLCO-2 (N.O.)contacts

Page 30 - ELECTRICAL OPERATION

VSX SERIES STEAMER - ELECTRICAL OPERATIONPage 36 of 80A. Boiler steam pressure is maintained by thecycling of the pressure switch between theupper an

Page 31

VSX SERIES STEAMER - ELECTRICAL OPERATIONPage 37 of 80A. The inverse latching relay of the waterlevel control is energized, changing thestate of ILR-

Page 32

VSX SERIES STEAMER - ELECTRICAL OPERATIONPage 38 of 80NOTE: LLCO relays will remain energized andLLCO LED’S will remain lit until the water leveldrop

Page 33

VSX SERIES STEAMER - ELECTRICAL OPERATIONPage 39 of 80A. Ready light (green) is lit.B. Product is inserted into steamer.C. Door is closed.D. Timer is

Page 34 - SEQUENCE OF OPERATION

VSX SERIES STEAMERS - GENERALPage 4 of 80VSX42RT SHOWNGENERALINTRODUCTIONGeneralThis manual is applicable for all models listed on thecover page. A c

Page 35

VSX SERIES STEAMER - ELECTRICAL OPERATIONPage 40 of 80PAGE PURPOSELY LEFT BLANK

Page 36

VSX SERIES STEAMER - ELECTRICAL OPERATIONPage 41 of 80SCHEMATICS, GAS STEAMERS, BOILER CONTROLS VSX24G, 36G AND 42GTManual Ignition, Standard Control

Page 37

VSX SERIES STEAMER - ELECTRICAL OPERATIONPage 42 of 80Electronic Ignition, Standard Controls

Page 38

VSX SERIES STEAMER - ELECTRICAL OPERATIONPage 43 of 80Manual Ignition, CSD-1 Code Controls

Page 39

VSX SERIES STEAMER - ELECTRICAL OPERATIONPage 44 of 80Electronic Ignition, CSD-1 Code Controls

Page 40 - PAGE PURPOSELY LEFT BLANK

VSX SERIES STEAMER - ELECTRICAL OPERATIONPage 45 of 80

Page 41 - VSX24G, 36G AND 42GT

VSX SERIES STEAMER - ELECTRICAL OPERATIONPage 46 of 80WIRING DIAGRAMS, GAS STEAMERS, BOILER CONTROLS VSX24G, 36G AND 42GT Manual Ignition, Standard

Page 42 - Page 42 of 80

VSX SERIES STEAMER - ELECTRICAL OPERATIONPage 47 of 80

Page 43 - Page 43 of 80

VSX SERIES STEAMER - ELECTRICAL OPERATIONPage 48 of 80Electronic Ignition, Standard Controls

Page 44 - Page 44 of 80

VSX SERIES STEAMER - ELECTRICAL OPERATIONPage 49 of 80

Page 45 - Page 45 of 80

VSX SERIES STEAMERS - GENERALPage 5 of 80SPECIFICATIONSGas SteamersINPUT(BTU/HR)MANIFOLDPRESSURE(INCHES W.C.) LINE PRESSURE(INCHES W.C.) LOAD (WA

Page 46

VSX SERIES STEAMER - ELECTRICAL OPERATIONPage 50 of 80 Manual Ignition, CSD-1 Code Controls

Page 47 - Page 47 of 80

VSX SERIES STEAMER - ELECTRICAL OPERATIONPage 51 of 80

Page 48 - Page 48 of 80

VSX SERIES STEAMER - ELECTRICAL OPERATIONPage 52 of 80Electronic Ignition, CSD-1 Code Controls

Page 49 - Page 49 of 80

VSX SERIES STEAMER - ELECTRICAL OPERATIONPage 53 of 80

Page 50 - Page 50 of 80

VSX SERIES STEAMER - ELECTRICAL OPERATIONPage 54 of 80SCHEMATICS, ELECTRIC STEAMERS, BOILER CONTROLS VSX24E, 36E AND 42ETAuto Blowdown, Standard Cont

Page 51 - Page 51 of 80

VSX SERIES STEAMER - ELECTRICAL OPERATIONPage 55 of 80Auto Blowdown, Cal-Code Controls

Page 52 - Page 52 of 80

VSX SERIES STEAMER - ELECTRICAL OPERATIONPage 56 of 80Auto Blowdown, Standard Controls

Page 53 - Page 53 of 80

VSX SERIES STEAMER - ELECTRICAL OPERATIONPage 57 of 80Auto Blowdown, Cal-Code Controls

Page 54 - VSX24E, 36E AND 42ET

VSX SERIES STEAMER - ELECTRICAL OPERATIONPage 58 of 80WIRING DIAGRAMS, ELECTRIC STEAMERS, BOILER CONTROLSVSX24E, 36E AND 42ET Auto Blowdown, Standar

Page 55 - Page 55 of 80

VSX SERIES STEAMER - ELECTRICAL OPERATIONPage 59 of 80

Page 56 - Page 56 of 80

VSX SERIES STEAMERS - OPERATIONPage 6 of 80Water SupplySupply pressure should be 20-80 psigIn line strainer for supply line (Not Supplied)Supply conn

Page 57 - Page 57 of 80

VSX SERIES STEAMER - ELECTRICAL OPERATIONPage 60 of 80 Auto Blowdown, Cal-Code Controls

Page 58

VSX SERIES STEAMER - ELECTRICAL OPERATIONPage 61 of 80

Page 59 - Page 59 of 80

VSX SERIES STEAMER - ELECTRICAL OPERATIONPage 62 of 80Auto Blowdown, Standard Controls

Page 60 - Page 60 of 80

VSX SERIES STEAMER - ELECTRICAL OPERATIONPage 63 of 80

Page 61 - Page 61 of 80

VSX SERIES STEAMER - ELECTRICAL OPERATIONPage 64 of 80Auto Blowdown, Step Down Transformer, Standard Controls

Page 62 - Page 62 of 80

VSX SERIES STEAMER - ELECTRICAL OPERATIONPage 65 of 80

Page 63 - Page 63 of 80

VSX SERIES STEAMER - ELECTRICAL OPERATIONPage 66 of 80 Auto Blowdown, Step Down Transformer, Cal-Code Controls (2 contactors)

Page 64 - Page 64 of 80

VSX SERIES STEAMER - ELECTRICAL OPERATIONPage 67 of 80

Page 65 - Page 65 of 80

VSX SERIES STEAMER - ELECTRICAL OPERATIONPage 68 of 80 Auto Blowdown, Step Down Transformer, Cal-Code Controls (4 contactors)

Page 66 - Page 66 of 80

VSX SERIES STEAMER - ELECTRICAL OPERATIONPage 69 of 80

Page 67 - Page 67 of 80

VSX SERIES STEAMERS - OPERATIONPage 7 of 80STEAMER OPERATIONWARNING: THE STEAMER AND ITS PARTS ARE HOT. USE CARE WHEN OPERATING, CLEANING ORSERVICING

Page 68 - Page 68 of 80

VSX SERIES STEAMER - ELECTRICAL OPERATIONPage 70 of 80WIRING DIAGRAMS, ELECTRIC HEATER CIRCUITSVSX24E, 36E AND 42ETStandard and Cal-Code/CSD-1 Contro

Page 69 - Page 69 of 80

VSX SERIES STEAMER - ELECTRICAL OPERATIONPage 71 of 80Standard and Cal-Code Controls (Older Models)

Page 70

VSX SERIES STEAMER - ELECTRICAL OPERATIONPage 72 of 803 Phase, 4 Wire (Older Models)

Page 71 - Page 71 of 80

VSX SERIES STEAMER - ELECTRICAL OPERATIONPage 73 of 80SCHEMATIC, DIRECT STEAMERS, CABINET BASEVSX24D, 36D AND 42DTSee “SCHEMATIC ALL MODELS - COMPART

Page 72 - Page 72 of 80

VSX SERIES STEAMER - ELECTRICAL OPERATIONPage 74 of 80WIRING DIAGRAMS, REGENERATED STEAMERS, BOILER CONTROLS VSX36R AND 42RT (OLDER MODELS)Manual Blo

Page 73 - VSX24D, 36D AND 42DT

VSX SERIES STEAMER - ELECTRICAL OPERATIONPage 75 of 80Auto Blowdown

Page 74 - Manual Blowdown

VSX SERIES STEAMER - ELECTRICAL OPERATIONPage 76 of 80SCHEMATIC ALL MODELS - COMPARTMENT CONTROLS

Page 75 - Auto Blowdown

VSX SERIES STEAMER - ELECTRICAL OPERATIONPage 77 of 80WIRING DIAGRAM, ALL MODELS - COMPARTMENT CONTROLS

Page 76 - Page 76 of 80

VSX SERIES STEAMER - TROUBLESHOOTING Page 78 of 80TROUBLESHOOTINGALL MODELSWARNING: CERTAIN PROCEDURES IN THIS SECTION REQUIRE ELECTRICAL TESTS ORMEA

Page 77 - Page 77 of 80

VSX SERIES STEAMER - TROUBLESHOOTING SYMPTOM POSSIBLE CAUSESPage 79 of 80Steam output low or slow cooking. 1. Blocked steam injector ports. (Open doo

Page 78 - TROUBLESHOOTING

VSX SERIES STEAMERS - OPERATIONPage 8 of 80Electrically Powered Steam BoilerOpen the cabinet door and turn main power switchON. The red light will il

Page 79

VSX SERIES STEAMER - TROUBLESHOOTING Form 24627 (December 98) Printed in U.S.A.GAS MODELS ONLYSYMPTOM POSSIBLE CAUSESBurner won’t light. 1. Gas not on

Page 80 - GAS MODELS ONLY

VSX SERIES STEAMERS - OPERATIONPage 9 of 80COOKING COMPARTMENTCONTROLSWhen the steam pressure in the cookingcompartment manifold reaches approximatel